What You Get
SpectraVision Horizontal | SpectraVision Vertical |
SpectraVision | Vertical Spectravision |
Datacolor Tools SV | Datacolor Tools SV |
Ethernet Cable | Ethernet Cable/td> |
Power Cable | Power Cable |
Calibration Kit included | Calibration Kit Included |
Sample Holder | One-year Hardware Warranty |
One-year Hardware Warranty | User Guides |
User Guides | Black Sample Tray |
Calibration stand | |
Sample cup | |
4 Grey foam pads |
* Support Languages for Datacolor Tools: English, German, French, Italian, Spanish, Korean, Simplified Chinese, Polish, Traditional Chinese, Japanese, Portuguese
Technical Specifications
SpectraVision | SpectraVision Vertical | |
---|---|---|
Instrument Type | Barium coated sphere with xenon flash lamp, Diffuse illumination, 8º viewing in conformance with CIE publication No. 15.2 Colorimetry | Barium coated sphere with xenon flash lamp, Diffuse illumination, 8º viewing in conformance with CIE publication No. 15.2 Colorimetry |
Light Source | Pulsed xenon, filtered to provide D65 illumination including UV component. | Pulsed xenon, filtered to provide D65 illumination including UV component. |
Sphere Diameter | Diameter 152 mm / 6.0 inches, Barium coated | Diameter 152 mm / 6.0 inches, Barium coated |
Wavelength Range | 400 – 700 nm | 400 – 700 nm |
Reporting interval | 10 nm | 10 nm |
Photometric range | 0 to 200% | 0 to 200% |
Spectral Analyzer | Hyperspectral imaging assembly with 31 narrow bands covering 400 to 700 nm. The imaging is with a scientific 90 db camera with a sCMOS sensor. | Hyperspectral imaging assembly with 31 narrow bands covering 400 to 700 nm. The imaging is with a scientific 90 db camera with a sCMOS sensor. |
20 read repeatability on white tile using double flash (CIELAB) (1) | 0.03 dE (max) | 0.03 dE (max) |
Inter-instrument agreement: reflectance measurements (CIELAB) (1,2 & 3) | 0.25 (max)* 0.15 (avg)* | 0.25 (max)* 0.15 (avg)* |
Lens | 50 mm, fixed focus | 50 mm, fixed focus |
Aperture Plates | Square. 25 mm illuminated/ 22.7 mm viewed | Square. 25 mm illuminated/ 22.7 mm viewed |
Automated, adjustable UV calibration | Yes | Yes |
UV cutoff filters | 400 nm; 420 nm; 460 nm | 400 nm; 420 nm; 460 nm |
Functional Operating Environment (2) | Temperature: 10°C to 35°C, Recommended Temperature: 23°C +/- 2°C, Maximum Relative Humidity: 20%-85% non-condensing, Recommended Relative Humidity: 50% +/-15% non-condensing, Altitude: Up to 2,000 meters, Do not store above 140°F (60°C), |
Temperature: 10°C to 35°C, Recommended Temperature: 23°C +/- 2°C, Maximum Relative Humidity: 20%-85% non-condensing, Recommended Relative Humidity: 50% +/-15% non-condensing, Altitude: Up to 2,000 meters, Do not store above 140°F (60°C), |
Vertical Mount | No | Yes |
Physical Specifications | ||
Power Requirements | Input Voltage: 100-240VAC, Frequency: 50/60 Hz, 150 VA Peak | Input Voltage: 100-240VAC, Frequency: 50/60 Hz, 150 VA Peak |
Power Consumption | 150VA | 150VA |
Weight | 70 lbs (31.75kg) | 146 lbs. (66.22 kgs) |
Dimensions | L 19.9” (50.6 cm) front to back L 21.71” (55.14 cm) sample arm to back H 15.17” x W 12.3” (38.54 cm x 31.3 cm) | Instrument body (top section): Depth (front to back) 13.5” (34.29 cm) Width 15” (38.1 cm) Instrument base (stand): Depth (front to back) 19” (48.26 cm) Width 19.5” (49.53 cm) Instrument standing height: Base feet to top of instrument 31.75” (80.64 cm) |
Additional Technical Specifications | ||
Data Interface | Ethernet | Ethernet |
Other Interface(s) | HDMI (Video)/USB:2.0 (Keyboard,Mouse) | HDMI (Video)/USB:2.0 (Keyboard,Mouse) |
Image Resolution | 821 x 821 | 821 x 821 |
Effective Pixel Size | 27.6 micrometers | 27.6 micrometers |
Output | QTX2, Reflectance Hypercube, QTX | QTX2, Reflectance Hypercube, QTX |
Additional Functional Data | ||
Software Connection | Tools SV | Tools SV |
(1) Environmental Conditions: Temperature 23°C +/- 1°C RH 50% +/- 10%
(2) For reliable color measurements, conditions must be within recommended operating conditions.
(3) Color equation is CIELab (D65/10), SAV, Specular Included, Measured on 12 BCRA Tiles
Software Requirements
Datacolor Tools SV
Component | Minimum Requirements |
Desktop | |
Processor | Intel i7 or Intel Xeon |
2 Cores | |
4.5 GHz | |
8 MB Cache | |
Memory RAM | 64 GB |
Hard Drive | SSD 1 TB Min, 4 TB (4TB only needed if not using external storage.) |
Video Resolution | 1920×1080 – size of text only 100% supported |
DVD Drive | DVD Writer |
Ports | 2 Ethernet ports with 1 GBPS (Gigabit Network) USB Port (2.0 Min) |
Operating System | Windows 10 Pro or Enterprise |
Authenticated Sybase Database, supplied with the system | Sybase 12.0.1 EBF3994 Rev 4. |
Optional Textile Database upon request | Microsoft SQL Server 2008, 2012 R2 |
Server OS | Microsoft SQL Server 2016 |